Meimandi, Crovetti, Citraro, Andriulli and Carrara, IEEE Sensors Letters 2026: the chain rebuilt as a model, its LNA and ring VCO rebuilt in SKY130, checked against the paper, then improved at the implant and at the receiver
Short report (PDF, 6 pages) Full report, implant side (PDF, 8 pages)
The paper's design against the proposal
Paper, measured: the letter's values. Paper, our model: the same chain in the Python models (checked in the Validation tab), with process, temperature, supply and mismatch from two SKY130 rebuilds of its ring: a faithful one with the Table 1 sizes at ±0.6 V (route A rows; it sits at 7 kHz instead of 245 kHz because SKY130 thresholds are higher) and one at ±0.9 V that sits at 240 kHz (route B rows). Proposed: the same model with the changes under By. Everything except the measured column is simulation.
The changes
The evidence in three plots
Proposed design: changes to the paper's link
Waveform viewer
Transient results of the link model (input, LNA, ring VCOs at 2 MHz sampling, body channel, receivers), shown as in a circuit simulator's waveform viewer. Each test overlays the paper's design and the proposal on the same axes, with markers already placed where the difference shows. Click to move marker A (shift-click: B), drag a marker to move it, drag across the plot to zoom, double-click to fit. Every result is computed once in your browser, so the readings do not move.
Your own run: set the channel and the catheter conditions, then press Run
The link, paper against proposed
A quarter second of synthetic neural recording (three units of 60 to 300 µV on a local field potential) goes through the whole chain: the LNA with the paper's band and noise, the ring VCO(s), the body channel and the receiver. The catheter adds 50 Hz ripple on the rails and the blood temperature rises during the record. Both designs see the same recording, the same channel and the same receiver noise. Change the loss and the conditions and run it again.
PAPER'S DESIGN
PROPOSED DESIGN
The paper's ring VCO, rebuilt in SKY130 (two ports)
Two rebuilds of the 3-stage current-starved ring of Fig. 2(c), simulated in ngspice with the open SKY130 models. The first keeps the paper's ±0.6 V and the Table 1 sizes and is the baseline for route A (P10); the second uses ±0.9 V and shorter inverters so that it sits at the paper's 240 kHz, and carries route B (P2 to P7). Both show the same thing: the control branch works in weak inversion, so the carrier is exponential in its control and in the threshold voltage. SKY130 is not the paper's TSMC 180 nm; the absolute values are not claimed for the paper's chip.
Faithful port at ±0.6 V, and route A (P10) at transistor level
The load-balancing amplifier and the ring VCO of Fig. 2(b), (c) with the Table 1 sizes at the paper's ±0.6 V, SKY130 low-threshold devices, ideal capacitors. SKY130 thresholds are higher than TSMC 180 nm's, and the push-pull control branch runs in deep weak inversion, so this port sits at 7 kHz instead of 245 kHz: the carrier is exponential in the threshold. The ring itself, fed an ideal current, is close to linear (). Route A replaces the load-balancing amplifier and the pair M27/M28 by a source-degenerated pair with a resistor tail, with the same ring, mirrors and buffers.
faithful port: f against vd, five corners, 27 C
route A: f against vd, five corners, 27 C
Port at ±0.9 V for route B (240 kHz)
The 3-stage current-starved ring of Fig. 2(c) with the bias stack and the Table 1 sizes, simulated in ngspice with the open SKY130 models and per-device Pelgrom mismatch. SKY130 is not the paper's TSMC 180 nm: its higher PMOS threshold needs a 1.8 V span (±0.9 V, the paper uses ±0.6 V) and the inverters use 0.4× the Table 1 lengths to keep the carrier near 240 kHz. The shapes and sensitivities are what the proposals use; the absolute values are not claimed for the paper's chip.
f against differential control voltage, 37 C
carrier against temperature and supply
Monte Carlo: gain seen by each read-out, 24 chips
fingerprint: ln(fA/fB) at rest, 37 against 41 C
Validation: the model against the paper's measurements
Before any proposal, the Python model of the paper's chain is checked against the measured numbers. The noise spectrum is fitted to two of them (the 15.5 and 5.55 µVrms integrals); everything else is a prediction of the model.
| Quantity | Paper (measured) | This model | Where |
|---|
Peak-to-peak frequency swing against input amplitude, as in Fig. 3(b): model (line), the paper's 347 Hz/µV slope and its saturation near 1050 kHz (dashed).
Swing against input frequency at 2 mVpp, as in Fig. 3(c); dashed lines at the paper's 6 Hz and 6.7 kHz corners.
How the model works
The paper
Meimandi et al. (EPFL Bio/CMOS Interfaces Lab with Politecnico di Torino) put a 0.0025 mm2 neural front end on the tip of a microcatheter for intravascular recording. A fully differential capacitive-feedback LNA drives a 3-stage current-starved ring VCO, and a buffer drives the carrier into the tissue for body-coupled communication: the neural signal is carried as frequency (Kvf = 347 Hz/µV around about 245 kHz), so the channel's loss scales the carrier's amplitude but not the signal. Measured in TSMC 180 nm: 11 µW, 6 Hz to 6.7 kHz, 5.55 µVrms in the spike band.
The model, in signal order
- Input: three units (300, 150 and 60 µV, biphasic, Poisson firing), a 1/f local field potential (30 µVrms), optionally a large slow wave.
- LNA: input-referred noise S(f) = a + c/fg fitted to the paper's 15.5 and 5.55 µVrms; 6 Hz high-pass, 6.7 kHz second-order low-pass; tanh saturation that sets the 1050 kHz limit of Fig. 3(b).
- VCO: f = f0 exp(k·y) with k = 347/245.5k per µV (the measured small-signal slope). The exponential law comes from the SKY130 rebuild and is the only law that lets the measured 694 kHz swing at 2 mVpp sit around a 245 kHz carrier. White-FM phase noise (-75 dBc/Hz at 10 kHz, an assumption). Temperature and supply sensitivity from SKY130.
- Body channel: flat loss and 20 nV/√Hz receiver-input noise (assumptions; real channels are frequency dependent).
- Receivers: the paper's zero-crossing read-out (band-pass 100 to 600 kHz, 1/period), reciprocal counting, and a second-order digital PLL (40 kHz loop) after a complex down-mix.
- Spike detection: 300 Hz to 6 kHz band-pass, threshold at 4.5 σ (median absolute deviation), matched to the ground truth within 0.6 ms; F1 score.
A second, independent study (route A and P10 to P16)
The implant-side proposals come from a separate rebuild: a Python model with a logistic (exponential, saturating) ring, fitted to the digitized Fig. 3 and checked against the measured numbers (carrier for 50 µVpp kHz, spike-band noise µVrms, dynamic range dB against 42.1 dB), SKY130 ports of the LNA and of the load-balancing amplifier and ring at ±0.6 V, and the proposed drive at transistor level over five corners and 27 to 47 °C. Its 8-page report is linked on the Overview. P10 to P16 in the tables come from this study.
What is assumed
Phase noise, the channel (flat loss, white noise), the neural signals, the ripple and temperature profiles. The browser simulator is a smaller port of the Python model (shorter records, lower sample rate), so its numbers agree statistically, not digit for digit. SKY130 is not the paper's process.
Source
Paper: A. Meimandi, P. S. Crovetti, E. Citraro, F. P. Andriulli and S. Carrara, "A 0.0025 mm2 CMOS neural front-end with VCO-based frequency encoding for body-coupled communication," IEEE Sensors Letters, vol. 10, no. 9, 2026, doi:10.1109/LSENS.2026.3716537. Its figures and numbers belong to its authors. Everything on this page is a simulation by Nithin Purushothama; nothing was fabricated or measured.