VCO-BCC Lab

a neural front end that encodes spikes as frequency for a body-coupled link, one fix at the implant, one at the receiver reportpapernithinpuru.com

Meimandi, Crovetti, Citraro, Andriulli and Carrara, IEEE Sensors Letters 2026: the chain rebuilt as a model, its LNA and ring VCO rebuilt in SKY130, checked against the paper, then improved at the implant and at the receiver

The paper's design against the proposal

Paper, measured: the letter's values. Paper, our model: the same chain in the Python models (checked in the Validation tab), with process, temperature, supply and mismatch from two SKY130 rebuilds of its ring: a faithful one with the Table 1 sizes at ±0.6 V (route A rows; it sits at 7 kHz instead of 245 kHz because SKY130 thresholds are higher) and one at ±0.9 V that sits at 240 kHz (route B rows). Proposed: the same model with the changes under By. Everything except the measured column is simulation.

The changes

Schematic of the proposed link with the changes in colour
The proposed link: the paper's front end (black; Fig. 2(c) and Table 1 of the letter, transistor-level ring M26-M45) with the changes in colour. Top row: the implant. Bottom row: the body channel and the external receiver. The paper's design alone is in the Proposed design tab.
Transistor-level schematic of the proposed resistor-defined voltage-to-current drive: a source-degenerated NMOS pair with a resistor tail and a diode load sets the bias voltages V_BP and V_BN of the paper's ring through M29, a copy transistor Mpc and M26

The evidence in three plots