Gupta, Damodaran, Liao, Seo and Sanyal, ISCAS 2026: the reservoir + delta-sigma CIM classifier rebuilt as a system model with SKY130 neuron data, checked against the paper, then improved
2-page summary (PDF) Earlier detailed report (PDF)
The paper's design against the proposal
Paper: the published system in this model (30 neurons with SKY130 Monte Carlo mismatch on ECG200, 8 chips x 10 train/test splits; readout trained with each chip in the loop at 27 C). Proposed: the same model with the changes under By. All numbers are simulation, read from the Python results; nothing here is measured.
The proposed circuit
The input layer moves on chip as a bitstream XNOR with SRAM power-up weights, and a label-free normalisation sits between the reservoir and the CIM column, whose weights are trained once on a nominal twin. Changes in the accent colour. The small plots trace one ECG beat through this circuit on chip 0.
The evidence in three plots
The classifier, original against proposed
ECG beats (ECG200, normal against myocardial ischemia) through the whole system of Gupta, Damodaran, Liao, Seo and Sanyal (ISCAS 2026): a random binary input layer, 30 switched-capacitor leaky-integrator neurons with ring coupling and threshold reset, an input delta-sigma modulator per feature, and a compute-in-memory output layer with 4-bit weights whose result is itself a delta-sigma bitstream. Every chip draws its own mismatch; with "SKY130" each neuron's amplifier gain, amplifier offset and comparator threshold come from a transistor-level Monte Carlo at the chosen temperature. The paper's design and the design you choose run on the same chip; the schematics redraw with every proposed change in the accent colour, and their small plots trace the chosen beat through the chosen chip.
PAPER'S DESIGN
PROPOSED DESIGN
Accuracy of each of the 8 chips (mean over 10 train/test splits).
The 30 features this beat produces (time-averaged neuron outputs) after each design's normalisation, as the DSM-CIM sees them (full scale = 1).
The blocks and their transistor-level data
SKY130 ngspice runs (open PDK, per-device Pelgrom mismatch) behind the block models. The paper's chip is in another process; the SKY130 numbers replace hand-picked mismatch values, they do not reproduce the paper's silicon.
Neuron amplifier: inverter at its trip point, 240 neurons
DC gain (-dVout/dVin at the trip point) of every neuron's amplifier, NMOS 0.84/0.18, PMOS 2.52/0.18 um at 1.2 V. The paper's amplifier gain is about 25.
Offsets: amplifier trip point and comparator threshold
SRAM power-up skew, 128 six-transistor cells (P4)
Input conditioning: bitstream input layer (P9)
A first-order delta-sigma modulator turns each ECG sample into L bits; XNOR gates apply the random ±1 weights to the bits and a charge-sharing sum averages them, so the input layer the paper computes off-chip costs gates on-chip.
Thirteen proposals, three rounds
Each proposal changes one or more blocks and is tested on the same system model (ECG200, 8 chips x 10 splits). The numbers come from the Python reference runs (results files of the repository, not typed by hand); the System and Fingerprint tabs rerun the main ones live. Negative results are kept.
| # | Proposal | Blocks changed | Python result | Verdict |
|---|
The reservoir as its own fingerprint (P12)
The neuron mismatch that costs accuracy when a readout moves between chips is also a physical signature. Eight stored beats are a challenge; the 30 averaged neuron responses are the chip's answer. Enrolment stores the answers at -40, 27 and 85 C; in use, the reference is interpolated at the on-chip temperature reading (±2 C error) and the nearest chip wins. The classifier can authenticate the sensor it runs on, with no extra circuit.
Left: RMS distance between each read (rows: chip, 4 reads each) and each enrolled reference (columns), darker = closer. Right: distances to the own reference against distances to the other chips' references.
Validation: browser model against the Python reference
The browser model is a port of the Python model with the same train/test splits; chip mismatch draws come from another random generator, so numbers agree statistically, within about one to two points on 80 test beats.
| Experiment | Python [%] | This browser [%] |
|---|
How the model works
The original system
The paper (an ASU-led ISCAS 2026 paper with Prof. Jae-sun Seo as co-author) classifies sensor sequences with an analog reservoir and a delta-sigma compute-in-memory layer. Every D = 32 input samples, each neuron receives a ±1-weighted sum of them (computed off-chip), integrates it on a switched-capacitor leaky integrator with a finite-gain amplifier (A about 25), hears its two ring neighbours through a soft-saturating output, and resets itself and its neighbours when it crosses a threshold. The time average of each neuron is a feature; a first-order delta-sigma modulator turns each feature into a bitstream, and the output layer multiplies the bits by 4-bit weights in the charge domain every cycle; its sum feeds a second delta-sigma modulator whose count is the decision. The readout is trained with the chip in the loop. On ECG200 a beat gives three reservoir steps.
Block models
- Input layer: random ±1 weights (fixed seed, as the paper's off-chip W), or SRAM power-up values (P4: SKY130 skews at -40, 27, 85 C, enrolment keeps cells stable at all three, 1 mV read noise), with analog or bitstream (P9) input.
- Neuron: v ← a v + Gi u + Gf (H(vleft) + H(vright)) + noise, leak a = 1 - (1 + Gi + 2Gf)/A, H = vsat tanh(v/vsat), reset with lateral inhibition. Mismatch per neuron in A, offsets, threshold, capacitor ratios and swing.
- Input DSM and DSM-CIM: first-order 1-bit modulators, column gain error (2 %) and MAC noise per cycle, OSR 10.
- Readout: logistic regression in software, weights quantised to 4 bits, MAC gain set so the output modulator uses its full scale. P7: a nominal twin (no mismatch) is trained with labels; each chip only measures the mean and spread of each neuron on unlabelled inputs.
What is assumed
Capacitor ratios, swing, thermal noise, column gain error and the round-1 mismatch scale (chosen so the cross-chip drop is about 3 points, as the paper measures); the inverter cell standing in for the paper's amplifier and comparator in the SKY130 runs. ECG200 is short; the paper's longer data sets (WESAD, seismic) were not available in this sandbox.
Source
Paper: T. Gupta, V. Damodaran, Y. Liao, J.-s. Seo and A. Sanyal, "Delta-sigma modulator-based compute-in-memory neural network with analog feature extraction and classification for edge sensors," Proc. IEEE ISCAS 2026, doi:10.1109/ISCAS66217.2026.11562729. Its figures and numbers belong to its authors. ECG200: UCR time-series archive. Everything on this page is a behavioural simulation by Nithin Purushothama; nothing was fabricated or measured.